What:           /sys/devices/uncore_iio_x/dieX
Date:           February 2020
Contact:        Alexander Antonov <alexander.antonov@linux.intel.com>
Description:
                Each IIO stack (PCIe root port) has its own IIO PMON block, so
                each dieX file (where X is die number) holds "Segment:Root Bus"
                for PCIe root port, which can be monitored by that IIO PMON
                block.
                For example, on 4-die Xeon platform with up to 6 IIO stacks per
                die and, therefore, 6 IIO PMON blocks per die, the mapping of
                IIO PMON block 0 exposes as the following:

                $ ls /sys/devices/uncore_iio_0/die*
                -r--r--r-- /sys/devices/uncore_iio_0/die0
                -r--r--r-- /sys/devices/uncore_iio_0/die1
                -r--r--r-- /sys/devices/uncore_iio_0/die2
                -r--r--r-- /sys/devices/uncore_iio_0/die3

                $ tail /sys/devices/uncore_iio_0/die*
                ==> /sys/devices/uncore_iio_0/die0 <==
                0000:00
                ==> /sys/devices/uncore_iio_0/die1 <==
                0000:40
                ==> /sys/devices/uncore_iio_0/die2 <==
                0000:80
                ==> /sys/devices/uncore_iio_0/die3 <==
                0000:c0

                Which means:
                IIO PMU 0 on die 0 belongs to PCI RP on bus 0x00, domain 0x0000
                IIO PMU 0 on die 1 belongs to PCI RP on bus 0x40, domain 0x0000
                IIO PMU 0 on die 2 belongs to PCI RP on bus 0x80, domain 0x0000
                IIO PMU 0 on die 3 belongs to PCI RP on bus 0xc0, domain 0x0000

What:           /sys/devices/uncore_upi_x/dieX
Date:           March 2022
Contact:        Alexander Antonov <alexander.antonov@linux.intel.com>
Description:
                Each /sys/devices/uncore_upi_X/dieY file holds "upi_Z,die_W"
                value that means UPI link number X on die Y is connected to UPI
                link Z on die W and this link between sockets can be monitored
                by UPI PMON block.
                For example, 4-die Sapphire Rapids platform has the following
                UPI 0 topology::

		    # tail /sys/devices/uncore_upi_0/die*
		    ==> /sys/devices/uncore_upi_0/die0 <==
		    upi_1,die_1
		    ==> /sys/devices/uncore_upi_0/die1 <==
		    upi_0,die_3
		    ==> /sys/devices/uncore_upi_0/die2 <==
		    upi_1,die_3
		    ==> /sys/devices/uncore_upi_0/die3 <==
		    upi_0,die_1

                Which means::

		    UPI link 0 on die 0 is connected to UPI link 1 on die 1
		    UPI link 0 on die 1 is connected to UPI link 0 on die 3
		    UPI link 0 on die 2 is connected to UPI link 1 on die 3
		    UPI link 0 on die 3 is connected to UPI link 0 on die 1
