#!/bin/sh
#
# 
# ICP
#
# Description:	Manages an ICP Vortex clustered host drive as an HA resource
#
#
# Author:	Lars Marowsky-Bree <lmb@suse.de>
# Support:	users@clusterlabs.org
# License:	GNU General Public License (GPL)
# Copyright:	(C) 2002 SuSE Linux AG
#
#
# An example usage in /etc/ha.d/haresources: 
#       node1  10.0.0.170 LinuxSCSI::0:0 ICP::c0h1::/dev/sdb1 LVM::myvolname
#
# Notice that you will need to get the utility "icpclucon" from the ICP
# support to use this.
#
# See usage() function below for more details...
#
#	  OCF parameters are as below:
#		OCF_RESKEY_driveid
#		OCF_RESKEY_device

#######################################################################
# Initialization:

: ${OCF_FUNCTIONS_DIR=${OCF_ROOT}/lib/heartbeat}
. ${OCF_FUNCTIONS_DIR}/ocf-shellfuncs

# Parameter defaults

OCF_RESKEY_driveid_default=""
OCF_RESKEY_device_default=""

: ${OCF_RESKEY_driveid=${OCF_RESKEY_driveid_default}}
: ${OCF_RESKEY_device=${OCF_RESKEY_device_default}}

#######################################################################

#
ICPCLUCON=/usr/sbin/icpclucon
#

usage() {
  methods=`ICP_methods | grep -v methods`
  methods=`echo $methods | tr ' ' '|'`
  cat <<-!
	usage: $0 ($methods)

	$0 manages an ICP Vortex clustered host drive.

	The 'start' operation reserves the given host drive.
	The 'stop' operation releses the given host drive.
	The 'status' operation reports whether the host drive is reserved.
	The 'monitor' operation reports whether the host drive is reserved.
	The 'validate-all' operation reports whether OCF instance parameters are valid.
	The 'methods' operation reports on the methods $0 supports

	!
}

meta_data() {
	cat <<END
<?xml version="1.0"?>
<!DOCTYPE resource-agent SYSTEM "ra-api-1.dtd">
<resource-agent name="ICP">
<version>1.0</version>

<longdesc lang="en">
Resource script for ICP. It Manages an ICP Vortex clustered host drive as an 
HA resource. 
</longdesc>
<shortdesc lang="en">Manages an ICP Vortex clustered host drive</shortdesc>

<parameters>
<parameter name="driveid" unique="0" required="1">
<longdesc lang="en">
The ICP cluster drive ID.
</longdesc>
<shortdesc lang="en">ICP cluster drive ID</shortdesc>
<content type="string" default="${OCF_RESKEY_driveid_default}" />
</parameter>

<parameter name="device" unique="0" required="1">
<longdesc lang="en">
The device name.
</longdesc>
<shortdesc lang="en">device</shortdesc>
<content type="string" default="${OCF_RESKEY_device_default}" />
</parameter>
</parameters>

<actions>
<action name="start" timeout="20s" />
<action name="stop" timeout="20s" />
<action name="status" depth="0" timeout="20s" interval="10s" />
<action name="monitor" depth="0" timeout="20s" interval="10s" />
<action name="validate-all" timeout="5s" />
<action name="meta-data" timeout="5s" />
</actions>
</resource-agent>
END
}

#
# methods: What methods/operations do we support?
#
ICP_methods() {
  cat <<-!
	start
	stop
	status
	monitor
	methods
	validate-all
	meta-data
	usage
	!
}

ICP_status() {
        local icp_out
        
        icp_out=$($ICPCLUCON -v -status $1)
        if [ $? -ne 0 ]; then
                ocf_log "err" "Hostdrive not reserved by us."
                return $OCF_ERR_GENERIC
        fi

        if expr match "$icp_out" \
                '.*Drive is reserved by this host.*' >/dev/null 2>&1 ; then
                ocf_log "info" "Volume $1 is reserved by us."
                return $OCF_SUCCESS
        elif expr match "$icp_out" \
                '.*Drive is not reserved by any host.*' >/dev/null 2>&1 ; then
                ocf_log "err" "Volume $1 not reserved by any host."
                return $OCF_NOT_RUNNING
        else
                ocf_log "err" "Unknown output from icpclucon. Assuming we do not have a reservation:"
		ocf_log "err" "$icp_out"
                return $OCF_NOT_RUNNING
        fi
}

ICP_report_status() {
  if ICP_status $1 ; then
	echo "$1: running"
	return $OCF_SUCCESS
  else
	echo "$1: not running"
	return $OCF_NOT_RUNNING
  fi
}


#
#	Monitor the host drive - does it really seem to be working?
#
#
ICP_monitor() {

  if
    ICP_status $1
  then
    return $?
  else
    ocf_log "err" "ICP host drive $1 is offline"
    return $OCF_NOT_RUNNING
  fi

}

Clear_bufs() {
    $BLOCKDEV --flushbufs $1
}

#
#	Enable ICP host drive
#
ICP_start() {

  ocf_log "info" "Activating host drive $1"
  ocf_run $ICPCLUCON -v -reserve $1
  if [ $? -ne 0 ]; then
  	ocf_log "info" "Forcing reservation of $1"
	ocf_run $ICPCLUCON -v -force $1 || return $OCF_ERR_GENERIC
  fi

  if
    ICP_status $1
  then
    : OK
    # A reservation isn't as prompt as it should be
    sleep 3
    return $OCF_SUCCESS
  else
    ocf_log "err" "ICP: $1 was not reserved correctly"
    return $OCF_ERR_GENERIC
  fi
}

#
#	Release the ICP host drive
#
ICP_stop() {

  ocf_log "info" "Releasing ICP host drive $1"
  ocf_run $ICPCLUCON -v -release $1 || return $OCF_ERR_GENERIC

  ocf_log "info" "Verifying reservation"
  if ICP_status $1 ; then
    ocf_log "err" "ICP: $1 was not released correctly"
    return $OCF_ERR_GENERIC
  fi
  return $OCF_SUCCESS
}

ICP_validate_all() {
  check_binary $BLOCKDEV
  check_binary $ICPCLUCON
  $ICPCLUCON -v -status $driveid >/dev/null 2>&1
  if [ $? -ne 0 ]; then
	ocf_log err "Invalid driveid $driveid"
	exit $OCF_ERR_ARGS
  fi

  if [ ! -b $device ]; then
	ocf_log err "Device $device is not a block device"
	exit $OCF_ERR_ARGS
  fi

# Do not know how to check the association of $device with $driveid.

  return $OCF_SUCCESS
}

#
#	'main' starts here...
#

if
  ( [ $# -ne 1 ] )
then
  usage
  exit $OCF_ERR_ARGS
fi

# These operations do not require OCF instance parameters to be set
case "$1" in

  meta-data)	meta_data
		exit $OCF_SUCCESS;;

  methods)	ICP_methods
		exit $OCF_SUCCESS;;
  
  usage)	usage
		exit $OCF_SUCCESS;;

  *)		;;
esac

if 
  [ -z "$OCF_RESKEY_driveid" ] 
then
  ocf_log err "Please specify OCF_RESKEY_driveid"
  exit $OCF_ERR_ARGS
fi

if [ -z "$OCF_RESKEY_device" ]; then
  ocf_log err "Please specify OCF_RESKEY_device"
  exit $OCF_ERR_ARGS
fi

driveid=$OCF_RESKEY_driveid
device=$OCF_RESKEY_device

# What kind of method was invoked?
case "$1" in

  start)	ICP_validate_all
		ICP_start $driveid
		Clear_bufs $device
		exit $?;;

  stop)		ICP_stop $driveid
		Clear_bufs $device
		exit $?;;

  status)	ICP_report_status $driveid
		exit $?;;

  monitor)	ICP_monitor $driveid
		exit $?;;

  validate-all)	ICP_validate_all
		exit $?;;

  *)		usage
		exit $OCF_ERR_UNIMPLEMENTED;;
esac